Model Number | RM-350 | RM-351 | RM-452 | RM-453 |
Available Ranges | 0.2V, 2V, 20V, 200V, 1000V | 0.2V, 2V, 20V, 200V, 1000V | 2V, 20V, 200V, 1000V | 2V, 20V, 200V, 1000V |
Digits | 3½ | 3½ | 4½ | 4½ |
Display | 0.56" LED | 0.6" LCD | 0.56" LED | 0.4" LCD |
Accuracy | ±(.05% rdg +.05%F.S.) | ±(.05% rdg +.05%F.S.) | ±0.02%FS | ±0.02%FS |
Input Impedance | 0.2V, 100MΩ;
2V, 1000MΩ; 20V, 1MΩ; 200V and 1000V, 10MΩ |
0.2V, 100MΩ;
2V, 1000MΩ; 20V, 1MΩ; 200V and 1000V, 10MΩ |
2V, 1000MΩ;
20V, 1MΩ; 200V & 1000V, 10MΩ |
2V, 1000MΩ;
20V, 1MΩ; 200V & 1000V, 10MΩ |
Operating Temperature | 0°C to +50°C | 0°C to +50°C | 0°C to +50°C | 0°C to +50°C |
Common Mode Range | -1.5V to +4V | -1.5V to +4V | ±2V | ±2V |
Power | +5VDC ±5% @200mA | +5VDC ±5% @6mA | +5VDC ±5% @140mA | +5VDC ±5% @10mA |
Update Rate | 3 Rdg/Sec | 3 Rdg/Sec | 3 Rdg/Sec | 3 Rdg/Sec |
MUX BCD output | Edge connector Model Only | Edge connector Model Only | ||
Connector Types | EC or TB (Terminal Block) | EC or TB (Terminal Block) | EC or TB (Terminal Block) | EC or TB (Terminal Block) |
Current measurement | ||||
Ratio measurement | ||||
Display hold | * | * | ||
Weight (metric) | 5 oz. (142g) | 5 oz. (142g) | 6 oz. (170g) | 6 oz. (170g) |
Data Sheets |
RM-350 RM-350TB |
RM-351 |
RM-452EC RM-452TB |
RM-453TB |
RM-350TB |
RM-350TB GREEN |
RM-452 |
RM-453 |
Factory Installed Options | RM-350 | RM-351 | RM-452 | RM-453 |
Large LED display | 0.8-inch | |||
Green, Orange, Yellow LEDs | ||||
Current Measurement | ||||
AC Measurement | ||||
Ratio Measurement | ||||
120/240VAC Power | ||||
AC Input & 120/240VAC Power | ||||
Ohms Input & 120/240VAC Power | ||||
5, 12, 24, 28, 48VDC Power (Isolated) | ||||
AC Input & 5, 12, 24, 28, 48VDC Power (Isolated) | ||||
Ohms Input & 5, 12, 24, 28, 48VDC Power (Isolated) | ||||
Display hold | Standard | Standard | ||
Zero offset | ||||
Special scaling | ||||
Accessories | ||||
Voltage Range Kit | N39-356 | N39-356 | N39-356 | N39-356 |
Mating Connector EC Type Main Board | N46-l07 | N46-l07 | N46-199 | N46-l99 |
Mating Connector EC Type Top Board | N46-l07 | N46-l07 | N46-107 | N46-l07 |
OUR PRODUCTS:
Voltage/Current Meters PM Series RM Series X Series Counters & Frequency Frequency Monitors Loop Meters Signal Conditioners |
CONTACT:
Phone: (619) 521-2161 Email: sales@nonlinearsystems.com |
SEND REPAIRS TO:
Non-Linear Systems 4142 Adams Ave #103-542 San Diego, CA 92116 Copyright © 2022, Nonlinear Systems. All Rights Reserved. |
For best viewing, turn phone sideways. | ||||
Model Number | RM-350 | RM-351 | RM-452 | RM-453 |
Available Ranges | 0.2V, 2V, 20V, 200V, 1000V | 0.2V, 2V, 20V, 200V, 1000V | 2V, 20V, 200V, 1000V | 2V, 20V, 200V, 1000V |
Digits | 3½ | 3½ | 4½ | 4½ |
Display | 0.56" LED | 0.6" LCD | 0.56" LED | 0.4" LCD |
Accuracy | ±(.05% rdg +.05%F.S.) | ±(.05% rdg +.05%F.S.) | ±0.02%FS | ±0.02%FS |
Input Impedance | 0.2V, 100MΩ;
2V, 1000MΩ; 20V, 1MΩ; 200V and 1000V, 10MΩ |
0.2V, 100MΩ;
2V, 1000MΩ; 20V, 1MΩ; 200V and 1000V, 10MΩ |
2V, 1000MΩ;
20V, 1MΩ; 200V & 1000V, 10MΩ |
2V, 1000MΩ;
20V, 1MΩ; 200V & 1000V, 10MΩ |
Operating Temperature | 0°C to +50°C | 0°C to +50°C | 0°C to +50°C | 0°C to +50°C |
Common Mode Range | -1.5V to +4V | -1.5V to +4V | ±2V | ±2V |
Power | +5VDC ±5% @200mA | +5VDC ±5% @6mA | +5VDC ±5% @140mA | +5VDC ±5% @10mA |
Update Rate | 3 Rdg/Sec | 3 Rdg/Sec | 3 Rdg/Sec | 3 Rdg/Sec |
MUX BCD output | Edge connector Model Only | Edge connector Model Only | ||
Connector Types | EC or TB (Terminal Block) | EC or TB (Terminal Block) | EC or TB (Terminal Block) | EC or TB (Terminal Block) |
Current measurement | ||||
Ratio measurement | ||||
Display hold | * | * | ||
Weight (metric) | 5 oz. (142g) | 5 oz. (142g) | 6 oz. (170g) | 6 oz. (170g) |
Data Sheets |
RM-350 RM-350TB |
RM-351 |
RM-452EC RM-452TB |
RM-453TB |
RM-350TB |
RM-350TB GREEN |
RM-452 |
RM-453 |
For best viewing, turn phone sideways. | ||||
Factory Installed Options | RM-350 | RM-351 | RM-452 | RM-453 |
Large LED display | 0.8-inch | |||
Green, Orange, Yellow LEDs | ||||
Current Measurement | ||||
AC Measurement | ||||
Ratio Measurement | ||||
120/240VAC Power | ||||
AC Input & 5, 12, 24, 28, 48VDC Power (Isolated) | ||||
Ohms Input & 120/240VAC Power | ||||
5, 12, 24, 28, 48VDC Power (Isolated) | ||||
AC Input & 5,12,24,28,48VDC Power (Isolated) | ||||
Ohms Input & 5, 12, 24, 28, 48VDC Power (Isolated) | ||||
Display hold | Standard | Standard | ||
Zero offset | ||||
Special scaling | ||||
Accessories | ||||
Voltage Range Kit | N39-356 | N39-356 | N39-356 | N39-356 |
Mating Connector EC Type Main Board | N46-l07 | N46-l07 | N46-199 | N46-l99 |
Mating Connector EC Type Top Board | N46-l07 | N46-l07 | N46-107 | N46-l07 |
OUR PRODUCTS:
Voltage/Current Meters - PM Series Voltage/Current Meters - RM Series Voltage/Current Meters - X Series Counters & Frequency Frequency Monitors Loop Meters Signal Conditioners |
CONTACT:
Phone: (619) 521-2161 Email: sales@nonlinearsystems.com |
SEND REPAIRS TO:
Non-Linear Systems 4142 Adams Ave #103-542 San Diego, CA 92116 Copyright © 2022, Nonlinear Systems. All Rights Reserved. |